Abernathy Chimney Care

Gas Fireplace Repair in La Canada Flintridge for Pilots, Igniters and Valves

Book This Job

What You Get

We test the ignition chain one part at a time instead of guessing: pilot flame, thermocouple or thermopile output, valve, wall switch and igniter. Parts come from the maker or its approved list, since a generic part changes what the appliance was tested with. Every fitting we touch is leak tested, and the flame is compared to the manual before we leave. You get a written record of the readings and the parts used.

Pilot flame shape inspected
Millivolt readings taken
Valve and igniter tested
Maker-approved parts used
Leak test on each fitting
Readings written on the invoice

The Usual Faults and How We Find Them

Behind nearly every gas unit that misbehaves sits one of a handful of components. On units with a standing pilot, the pilot heats a thermocouple or thermopile, and the few millivolts that heat produces are what keep the valve's magnet holding gas on. When that part weakens, or when soot and dust coat it, the voltage drops and the valve closes, so the pilot dies the moment the knob is released or the main burner refuses to come on. Units with electronic ignition use a spark igniter and a flame sensor instead, plus a control module and often a battery backup, and they fail in their own ways: a click with no flame, a flame that lights and then drops out, a remote that stopped talking to the receiver. Then there are the venting faults, where a blocked termination or a cracked pipe makes the safety controls shut the unit down. Each of these looks similar from the sofa, which is why guessing at parts gets expensive.

We test rather than swap. The pilot assembly is cleaned and checked first, since a dirty pilot causes a large share of service calls. The thermocouple or thermopile output is read with a meter and compared to what the maker specifies, and the valve is checked to see whether it responds. On electronic units we test the igniter, the sensor and the module in turn. The vent is inspected inside and out, and the exterior cap is checked for nests, leaves and wind-blown debris, which near the slopes can pile up fast after a dry wind. If the unit also has an oxygen depletion sensor, as vent-free models do, we check that it trips when it should. When the faulty part is found, the repair price is written down before we fit it, and the unit is then lit and watched through a full cycle with the fittings leak checked.

Repair or Replace, and Getting Ready for Winter

Most repairs are a single part and a clean, and they make good sense. The question changes with older units. Some makers no longer supply parts for models sold decades ago, and some fireboxes have rusted or warped after years of service. In that case we say so and lay out the choices: a used or compatible part where one is safe to fit, or a replacement unit or insert sized to the opening. Replacing an old gas unit can also be the moment to choose a sealed direct vent model, which takes its combustion air from outside and keeps the room air out of the fire. We give you the price of the repair and, if it applies, the price range of a replacement, so the decision is made on real numbers. Our price list puts a gas insert, fitted into the firebox you have now, at $2,900 to $5,800.

For homes in La Canada Flintridge, a working gas fireplace is worth more than comfort. On no burn days under Rule 445, wood fires are off the table but gas is allowed, and on a red flag evening when nobody should be sending sparks up a chimney, gas gives you a fire without that worry. That makes fall the sensible time to have a faulty unit looked at, before you need it. Safety first, though: if there is a gas odor anywhere near the unit, leave the controls alone, do not switch lights on or off, get everyone outside and phone the gas utility once you are clear of the house. When the utility has made things safe, we can come out to find the fault. On the booking form, give the brand and model where the label is readable and describe what the unit does or does not do when you try to light it.

The Way Abernathy Chimney Care Works

Screen First

The cap mesh is looked at on every visit

Photo Report

Hazards listed first, each with a picture

Quote on Paper

Repairs priced line by line before work

Clean Hearth

Ash and soot leave the house with us

Other Jobs We Handle

Chimney Sweep

Creosote and soot pulled out of the flue before the dry months, so a stray spark finds less fuel above the firebox.

Open →

Chimney Inspection

A look at every place an ember could slip out of the flue, or a gust could push one back in.

Open →

Chimney Repair

Broken masonry, loose cap mounts and open joints closed up so heat, sparks and rain each stay where they belong.

Open →

Fireplace Inspection

Firebox, hearth and nearby trim measured, so a popping log or rolling coal lands on something that cannot burn.

Open →

Fireplace Repair

Firebrick, refractory panels, glass doors and mesh screens repaired so sparks stay inside the box where they started.

Open →

Chimney Level 2 Inspection

Video from firebox to cap, plus the attic and crawl space, ordered after a sale, a fire, a quake or a new appliance.

Open →

Chimney Cap Installation

A metal hood with an ember screen that keeps sparks in, rain out and birds from nesting, fastened to ride out Santa Ana gusts.

Open →

Chimney Flashing Repair

Leaking metal at the roofline replaced with layered step and counter pieces, plus a cricket where water piles up.

Open →

Chimney Masonry Repair

Worn joints repointed and flaking brick swapped out, closing the gaps heat could reach and water could soak.

Open →

Chimney Rebuilds

Chimneys too loose to repair taken down and built again to current height, steel and clearance rules.

Open →

Fireplace Cleaning

Ash, soot and old coals cleared from the firebox and doors, so the surfaces can be judged and nothing smolders unseen.

Open →

Gas Fireplace Cleaning

Burner, pilot, logs and glass serviced to the maker's manual, with the outside vent cleared of dry leaves and nests.

Open →

Fireplace Remodel

Mantel, face and hearth redesigns that keep wood back from the opening and give stray embers a wide stone landing.

Open →

Fireplace Inserts

A sealed firebox set into an open fireplace and lined to the top, ending the sparks an open hearth throws.

Open →

Pellet Stove Repair

We pull the stored fault history first and work back through feed, ignition, fans and the safety circuit; no switch gets bypassed.

Open →

Wood Stove Repair

Door seals, baffles, firebrick and glass renewed with parts for the model, and distances to walls measured.

Open →

Gas Logs

Log sets matched to the firebox and the room, with the damper blocked from closing on vented installs and the gas run permitted.

Open →

Chimney Seismic Retrofit

Bracing, strapping or a lighter top section, so a quake does not drop brick through the roof or leave a broken flue.

Open →

Chimney Crown Repair

Cracked chimney tops sealed or recast so winter rain stays out and the spark cap has solid footing.

Open →

Dryer Vent Cleaning

Lint cleared from the duct and the outside hood, so a hot dryer is not pushing air through a packed tube.

Open →

Chimney Liner Installation

A continuous stainless liner where cracked tile would otherwise let heat reach the framing around the flue.

Open →

Chimney Leak Repair

Winter leaks traced to the actual entry point and closed, whether it is metal, crown, cap or porous brick.

Open →

Chimney Waterproofing

A breathable water repellent on sound brick, applied once the joints and crown are tight.

Open →

Chimney Damper Repair

Rusted or warped dampers repaired or replaced so the flue closes off between fires and opens fully for one.

Open →

Chimney Chase Cover

Rusted tops on framed chimney chases replaced with a heavier custom pan that sheds water and seats the spark cap.

Open →
Call (747) 224-9058